TENT Central Air Conditioning is a subsidiary of TENT Group, which was founded in 1999 and is involved in industries such as membrane structure, environmental engineering, and central air conditioning.which is engaged in the research, production and sales of fresh air conditioner, rooftop air conditioner, floor standing air conditioner, air-cooled modular chillers, purification air conditioners and so on.
Why Choose Us
Our Factory
The company has three major manufacturing bases in Jiangsu and Hebei, covering a total area of 50,000 square meters, and its sales and installation service network is spread all over the country. It has 400+ employees and 90+ products.
Production Equipment
Our production equipment includes 1 set fully automatic uncoiling and leveling machine, 2 sets 3kW laser cutting machines, 7 sets bending machines, 2 sets high-precision turret punching machines, 3 sets closed high-speed punching machines, 2 sets long U-shaped pipe bending machines, 2 sets non shrinkage expansion pipe machines, 10 sets final assembly production lines, and 2 sets foam workshops
Certifications
The rooftop air conditioner has obtained many industry-leading technology certifications, such as first-class energy efficiency certification, CRAA certification, energy saving certification, CCC certification and so on.
Production Market
North and East China regions: Sales centers in Beijing, Tianjin, Hebei, and Shanxi, as well as sales centers in Shanghai, Nanjing, Suzhou, Xuzhou, Hangzhou, Ningbo, Jinan, and Qingdao.
Central and South China regions: Sales centers in Wuhan and Zhengzhou, as well as sales centers in Xiamen, Nanchang, Changsha, and Guangzhou.
Western, Northwest, and Northeast regions: Sichuan, Xi'an, and Northeast sales centers.
Oversea regions: Russia, Uzbekistan, Mexico and so on.
Advantages of Ceiling AHU
Filtration
AHUs typically contain filters that capture dust, pollen, pet dander, and other particulate matter present in the air. These filters help to remove contaminants, thereby enhancing the overall air quality.
01
Ventilation
AHUs regulate the exchange of indoor and outdoor air, ensuring a constant supply of fresh air while expelling stale or contaminated air. This process helps dilute indoor pollutants and maintain optimal indoor air quality levels.
02
Humidity Control
Many AHUs are equipped with humidifiers and dehumidifiers to regulate indoor humidity levels. By maintaining appropriate humidity levels, AHUs help prevent the growth of mold and mildew, which can degrade air quality and pose health risks.
03
Temperature Regulation
AHUs can also control indoor temperature, ensuring comfort for building occupants. Proper temperature control can help reduce the spread of airborne contaminants and maintain a healthier indoor environment.
04
Air Purification
Some advanced AHUs incorporate additional features such as UV germicidal lamps or photocatalytic oxidation systems, which help to neutralize bacteria, viruses, and other pathogens present in the air, further enhancing air quality.
05
Types of Ceiling AHU
Large Space (Drug Shade Storage) Jet Air Handling Unit
Large space jet AHU is an air conditioning equipment specially developed for large space places such as factories and drug storage facilities.
Large Space (Factory) Jet Air Handling Unit
Large space jet AHU is an air conditioning equipment specially developed for large space places such as factories and drug storage facilities. This device comes with a built-in cooling and heating source as well as a control system, eliminating the need for dedicated personnel to manage and maintain it.


Duct Air Handling Unit
The ceiling air handling unit is composed of filters, finned heat exchangers, fans, and motors, which can meet the requirements of various residual pressures, air volumes, and air outlet forms.
Jet Air Handling Unit
Jet air handing unit is the new unit which developed for customers by Tent. The unit is a suspended ceiling structure, using a spherical nozzle with superior performance as the air outlet,which can achieve long-distance direct air supply without air duct, save space, reduce the floor height, and greatly reduce the one-time investment cost.
Specifications
|
Model |
EKDW |
EKDW |
EKDW |
EKDW |
EKDW |
EKDW |
EKDW |
EKDW |
EKDW |
EKDW |
EKDW |
|
|
Nominal air flow (m3/h) |
2000 |
3000 |
4000 |
5000 |
6000 |
7000 |
8000 |
9000 |
10000 |
12000 |
13500 |
|
|
External residual pressure (Pa) |
I |
80 |
80 |
80 |
80 |
80 |
80 |
80 |
80 |
~ |
~ |
~ |
|
II |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
|
|
III |
220 |
220 |
220 |
220 |
220 |
220 |
220 |
220 |
220 |
220 |
220 |
|
|
IV |
~ |
~ |
~ |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
300 |
|
|
Nominal cooling capacity (kW) |
4 rows of coils (return air) |
12 |
17 |
24 |
31 |
38 |
44 |
51 |
56 |
63 |
74 |
81 |
|
4 rows of coils (fresh air) |
29 |
42 |
57 |
69 |
83 |
94 |
113 |
127 |
142 |
169 |
175 |
|
|
6 rows of coils (return air) |
15 |
23 |
33 |
39 |
48 |
55 |
63 |
72 |
78 |
94 |
107 |
|
|
6 rows of coils (fresh air) |
35 |
53 |
69 |
88 |
105 |
122 |
137 |
155 |
173 |
208 |
237 |
|
|
Nominal heating capacity (kW) |
4 rows of coils (return air) |
19 |
30 |
41 |
50 |
61 |
71 |
83 |
93 |
103 |
122 |
140 |
|
4 rows of coils (fresh air) |
33 |
49 |
66 |
82 |
99 |
115 |
133 |
148 |
161 |
197 |
220 |
|
|
6 rows of coils (return air) |
23 |
36 |
48 |
60 |
72 |
84 |
96 |
108 |
120 |
144 |
162 |
|
|
6 rows of coils (fresh air) |
38 |
57 |
77 |
95 |
114 |
132 |
150 |
169 |
188 |
224 |
255 |
|
|
Nominal cooling water flow (L/S) |
4 rows of coils (return air) |
0.57 |
0.81 |
1.14 |
1.48 |
1.81 |
2.10 |
2.43 |
2.67 |
3.00 |
3.52 |
3.86 |
|
4 rows of coils (fresh air) |
1.38 |
2.00 |
2.71 |
3.29 |
3.95 |
4.48 |
5.38 |
6.05 |
6.76 |
8.05 |
8.33 |
|
|
6 rows of coils (return air) |
0.71 |
1.10 |
1.57 |
1.86 |
2.29 |
2.62 |
3.00 |
3.43 |
3.71 |
4.48 |
5.10 |
|
|
6 rows of coils (fresh air) |
1.67 |
2.52 |
3.29 |
4.19 |
5.00 |
5.81 |
6.52 |
7.38 |
8.24 |
9.90 |
11.29 |
|
|
Nominal heating water flow (L/S) |
4 rows of coils (return air) |
0.43 |
0.68 |
0.92 |
1.13 |
1.37 |
1.71 |
1.87 |
2.24 |
2.32 |
2.75 |
3.37 |
|
4 rows of coils (fresh air) |
0.74 |
1.10 |
1.49 |
1.85 |
2.23 |
2.77 |
2.99 |
3.56 |
3.62 |
4.44 |
5.29 |
|
|
6 rows of coils (return air) |
0.52 |
0.81 |
1.08 |
1.35 |
1.62 |
2.02 |
2.16 |
2.60 |
2.70 |
3.24 |
3.90 |
|
|
6 rows of coils (fresh air) |
0.86 |
1.28 |
1.73 |
2.14 |
2.57 |
3.17 |
3.38 |
4.06 |
4.23 |
5.04 |
6.13 |
|
Key Differences Between AHUs And FCUs
Scale and Capacity
One of the most significant differences between AHUs and FCUs is the scale at which they operate. AHUs are designed for large-scale air handling, capable of conditioning and distributing air across multiple zones or an entire building. In contrast, FCUs are smaller units intended for localized temperature control in individual rooms or small areas.
Air Handling and Ventilation
AHUs are responsible for not only heating and cooling but also for managing ventilation, building pressure and air quality. They can handle large volumes of outside air, which is crucial for maintaining indoor air quality in commercial and industrial settings. FCUs, on the other hand, do not typically handle outside air and are focused solely on temperature control. This makes AHUs essential for buildings that require ventilation and fresh air intake, while FCUs are more suited for spaces where only localized temperature control is needed.
Installation and Maintenance
AHUs are typically larger, more complex systems that require dedicated space for installation, such as mechanical rooms or rooftops. Their maintenance involves regular checks of components like filters, coils, fans, and control systems, often requiring specialized knowledge and equipment. FCUs are smaller, simpler units that are easier to install and maintain. They are often installed in ceilings, walls, or floors, and their maintenance primarily involves cleaning or replacing filters and checking the operation of fans and coils.
Energy Efficiency and Control
AHUs, being part of a central HVAC system, can be controlled by a Building Management System (BMS), allowing for centralized control and monitoring of energy use. This can lead to more efficient operation, especially in large buildings. FCUs, with their localized control, offer flexibility in energy use but may not be as efficient in large-scale applications where centralized control would be more effective.
Packaging and delivery
|
Packaging Details |
Ceiling AHU Sea way: Export standard paper carton; |
|
Supply Ability |
20000 Unit/Units per Month |
Our Certificate






FAQ
We're well-known as one of the leading ceiling ahu manufacturers and suppliers in China. Be free to wholesale customized ceiling ahu from our factory. Contact us for more cheap products.
rooftop air conditioner for retail stores, rooftop air conditioner for offices, air conditioning for guava orchards